Diffusion Potentials Across an Artificial Membrane

Membrane properties of Nafion epithelium (the base line for de-focus driven ocular growth)

SETUP AND PREPARATIONS

CHLORIDING THE ELECTRODE (Ag/Cl)
IMG0167A.jpg


IMG0170A.jpg

 SETUP OF THE SOLUTIONS AND USSING CHAMBER

IMG0172A.jpg

USSSING CHAMBER
IMG0173A.jpg


SOLUTION FILLED USSING CHAMBER WITH ELECTRODES
IMG0174A.jpg


TOP VIEV OF RECORDING THE POTENTIAL
IMG0175A.jpg


NAFION 324 IN USSING CHAMBER
IMG0177A.jpg
IMG0178A.jpg


Results so far... (subject to change)


Asymmetry potential _ 0.6 mV_

Nafion 115

Table 1 Diffusion Potential of Nafion 115
Test number

1
2
3
4
5
6
7
8

Concentration of NaCl (Molarity)

Chamber 1

0.001
0.001
0.001
0.002
1.0
1.0
1.0
1.0
Chamber 2
0.001
0.01
0.1
1
0.002
0.01
0.1
1
Concentration Difference
1 X
10 X
100 X
500 X
500 X
100 X
10 X
1 X
Diffusion Potential reading(mV)
a.
0
-111.3

-125.0
114
85.4
2.5
0

b.
0
-108.5

-123.5
113.6
86.5
2.4
0
c.
0
-105.2

-123.2
113.3
66.4
2.3
0
Corrected Average reading*(mV)


-108.93

-124.5
113.03
78.83
1.8
0










* Average reading minus asymmetry potential


Nafion 324

Table 2 Diffusion Potential of Nafion 324
Test number

1
2
3
4
5
6
7
8

Concentration of NaCl (Molarity)

Chamber 1

0.001
0.001
0.001
0.002
1.0
1.0
1.0
1.0
Chamber 2
0.001
0.01
0.1
1
0.002
0.01
0.1
1
Concentration Difference
1 X
10 X
100 X
500 X
500 X
100 X
10 X
1 X
Diffusion Potential reading (mV)
a.
0
-26.6

-104.4
115
75.4
2.4
0

b.
0
-27.5

-104.
114.1
75.6
1.7
0

c.
0
-28.6

-104.1
113.2
75.4
1.8
0
Corrected Average reading* (mV)


-28.17


-104.8
113.5
74.867
1.37
0










* Average reading minus asymmetry potential